CodeDescriptionUnit
ACCU-D-2887n-Hexadecane & n-Octadecane - ASTM-D2887 Column Test Mix, 1% w/v in n-Octane1 mL
ACCU-D-3120-92-CAL-SETSulfur Calibration Set8 x 1 mL
ACCU-D-3230-89-1ASTM D-3230 Mixed Salt Solution, Varied conc, in Butanol:Methanol (63:37)100 mL
ACCU-D-3230-89-5ASTM D-3230 Mixed Salt Solution, Varied conc, in Butanol:Methanol (63:37)500 mL
ACCU-D-3237-01D-3237 Lead Calibration Level I Blank, MIBK:Aliquat 336 (99:1)100 mL
ACCU-D-3237-02D-3237 Lead Calibration Level II, 0,02 g Pb/gal, in 1% Aliquat 336:MIBK100 mL
ACCU-D-3237-03D-3237 Lead Calibration Level III, 0,05 g Pb/gal, in 1% Aliquat 336:MIBK100 mL
ACCU-D-3237-04D-3237 Lead Calibration Level IV, 0,10 g Pb/gal, in 1% Aliquat 336:MIBK100 mL
ACCU-D-3237-CAL-SETD-3237 Lead Standard Calibration Curve4 x 100 mL
ACCU-D-3524-CAL-10ML-SETD-3524 Calibration Set6 x 10 mL
ACCU-D-3524-CAL-5ML-SETD-3524 Calibration Set6 x 5 mL
ACCU-D-3524-CRD-3524 Column Resolution Mix, 1,0% by volume in Heptane1 mL
ACCU-D-3524-CR-PAKD-3524 Column Resolution Mix, 1,0% by volume in Heptane5 x 1 mL
ACCU-D-3524-IS-10MLD-3524 Internal Standard Solution, Varied conc, in Heptane10 mL
ACCU-D-3524-IS-10ML-PAKD-3524 Internal Standard Solution, Varied conc, in Heptane5 x 10 mL
ACCU-D-3524-QC-10MLD-3524 Mid Level Daily QC Solution, Varied conc, by weight10 mL
ACCU-D-3606/IS-2ML-SETASTM D-3606 Aromatics Calibration Set7 x 2 mL
ACCU-D-3606/IS-2ML-SET-PAKASTM D-3606 Aromatics Calibration Set5 x (7 x 2 mL)
ACCU-D-3606/IS2-R1-SETAromatics Quantitative Calibration Curve7 x 1 mL
ACCU-D-3606/IS2-SETD-3606 Calibration Set with ISTD sec-butanol7 x 1 mL
ACCU-D-3606/IS2-SET-PAKD-3606 Calibration Set with ISTD sec-butanol5 x (7 x 1 mL)
ACCU-D-3606/IS-SETASTM D-3606 Aromatics Calibration Set7 x 1 mL
ACCU-D-3606-25ML-SETASTM D-3606 Aromatics Calibration Set7 x 25 mL
ACCU-D-3606-QC/IS-10MLASTM D-3606 Daily QC Std with Internal Standard, Varied conc, by v/v%10 mL
ACCU-D-3606-QC/IS-10ML-PAKASTM D-3606 Daily QC Std with Internal Standard, Varied conc, by v/v%5 x 10 mL
ACCU-D-3606-QC-25MLDaily QC Standard without Internal Std, Varied conc,25 mL
ACCU-D-3606-QC-25ML-PAKDaily QC Standard without Internal Std, Varied conc,5 x 25 mL
ACCU-D-3606-QC-IS2-25MLD-3606 Calibration Standard 04 with ISTD sec-butanol, Varied vol% in Isooctane25 mL
ACCU-D-3606-QC-IS2-25ML-PAKD-3606 Calibration Standard 04 with ISTD sec-butanol, Varied vol% in Isooctane5 x 25 mL
ACCU-D-3710Quantitative Calibration Mix, Varied conc, by %v/v1 mL
ACCU-D-3710-PAKQuantitative Calibration Mix, Varied conc, by %v/v5 x 1 mL
ACCU-D-3710-QUALD-3710 Qualitative Calibration Standard, Varied conc, by weight1 mL
ACCU-D-3710-QUAL-PAKD-3710 Qualitative Calibration standard, Varied conc, by weight5 x 1 mL
ACCU-D-3798-10MLD-3798 P-Xylene Impurity Standard without IS, Varied conc, by weight10 mL
ACCU-D-3798-10ML-PAKD-3798 P-Xylene Impurity Standard without IS, Varied conc, by weight5 x 10 mL
ACCU-D-3798-ISD-3798 P-Xylene Impurity Standard with IS, Varied conc, by %w/w1 mL
ACCU-D-3798-IS-PAKD-3798 P-Xylene Impurity Standard with IS, Varied conc, by %w/w5 x 1 mL
ACCU-D-3831-1D-3831 Stock Manganese Solution, 1 g/gal in Methyl isobutyl ketone100 mL
ACCU-D-4629-91-HB-0.3XNitrogen, 0,3 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-100XNitrogen, 100 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-10XNitrogen, 10,0 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-1XNitrogen, 1,0 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-25XNitrogen, 25,0 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-50XNitrogen, 50,0 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-75XNitrogen, 75,0 µg/mL in Toluene1 mL
ACCU-D-4629-91-HB-CONNitrogen Solution for High Boiling Solvents, 1000 µg/mL in Toluene:Acetone (9:1)1 mL
ACCU-D-4629-91-HB-CON-PAKNitrogen Solution for High Boiling Solvents, 1000 µg/mL in Toluene:Acetone (9:1)5 x 1 mL
ACCU-D-4629-91-LB-0.3XNitrogen Standard, 0,3 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-100XNitrogen Standard, 100 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-10XNitrogen Standard, 10,0 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-1XNitrogen Standard, 1,0 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-25XNitrogen, 25,0 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-50XNitrogen, 50,0 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-75XNitrogen, 75,0 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-CONNitrogen Solution for Low Boiling Solvents, 1000 µg/mL in Isooctane1 mL
ACCU-D-4629-91-LB-CON-PAKNitrogen Solution for Low Boiling Solvents, 1000 µg/mL in Isooctane5 x 1 mL
ACCU-D-4629-HB-CAL-R1-SETNitrogen Calibration Set - High Boiling Solvents8 x 1 mL
ACCU-D-4629-LB-CAL-R1-SETNitrogen Calibration Set - Low Boiling Solvents8 x 1 mL
ACCU-D-4815/IS-SETASTM D-4815 Oxygenates Solutions w/ IS Set5 x 1 mL
ACCU-D-4815/IS-SET-PAKASTM D-4815 Oxygenates Solutions w/ IS Set5 x (5 x 1 mL)
ACCU-D-4815-10ML-SETASTM D-4815 Oxygenates Calibration Solutions Set5 x 10 mL
ACCU-D-4815-RTASTM D-4815 Retention Time Mixture, Varied conc, by weight1 mL
ACCU-D-4815-RT-PAKASTM D-4815 Retention Time Mixture, Varied conc, by weight5 x 1 mL
ACCU-D-4815-VTASTM D-4815 Valve Timing Solution, Varied conc, by weight1 mL
ACCU-D-4815-VT-PAKASTM D-4815 Valve Timing Solution, Varied conc, by weight5 x 1 mL
ACCU-D-4929-94D-4929 Working Level Chlorine Standard, 10 µg/mL in Isooctane5 mL
ACCU-D-4929-94-100XD-4929 Stock Chlorine Standard, 1000 µg/mL in Isooctane5 mL
ACCU-D-4929-94-100X-PAKD-4929 Stock Chlorine Standard, 1000 µg/mL in Isooctane5 x 5 mL
ACCU-D-4929-94-PAKD-4929 Working Level Chlorine Standard, 10 µg/mL in Isooctane5 x 5 mL
ACCU-D-5134-92-ALKAlkylate Standard Mix, Varied conc, by %w/w1 mL
ACCU-D-5134-92-CEMColumn Evalution Mix, Varied conc, by %w/w1 mL
ACCU-D-5134-92-LCM-PAKLinearity check Mix, 10% w/w each component5 x 50 mg
ACCU-D-5134-92-NAPNaphtha Standard Mix1 mL
ACCU-D-5134-92-REFReformate Standard Mix, Varied conc, by %w/w1 mL
ACCU-D-5134-92-SETQualitative Reference Petroleum Set3 x 1 mL
ACCU-D-5186-96-PMD-5186-96 Performance Solution, Varied conc, by %w/w1 mL
ACCU-D-5186-96-PM-PAKD-5186-96 Performance Solution, Varied conc, by %w/w5 x 1 mL
ACCU-D-5307-CRD-5307 Column Resolution Mixture, Varied conc, by weight1 mL
ACCU-D-5307-CR-PAKD-5307 Column Resolution Mixture, Varied conc, by weight5 x 1 mL
ACCU-D-5307-IS-10MLD-5307 Internal Standard, Varied conc, by weight10 mL
ACCU-D-5307-IS-10ML-PAKD-5307 Internal Standard, Varied conc, by weight5 x 10 mL
ACCU-D-5307-QUALD-5307 Qualitative Paraffins Standard, Varied conc, by weight1 mL
ACCU-D-5307-QUAL-PAKD-5307 Qualitative Paraffins Standard, Varied conc, by weight5 x 1 mL
ACCU-D-5307-QUANTD-5307 Quantitative Paraffins Standard, 6,25%w/w per component2 mL
ACCU-D-5307-QUANT-PAKD-5307 Quantitative Paraffins Standard, 6,25%w/w per component5 x 2 mL
ACCU-D-5441ASTM D5441 MtBE Contaminant Std, Low Conc,, 0,1 % w/w in MtBE1 mL
ACCU-D-5441-10XASTM D5441 MtBE Contaminant Std, High Conc,, 1,0 % w/w in MtBE1 mL
ACCU-D-5441-10X-5MLASTM D5441 MtBE Contaminant Std, High Conc,, 1,0 % w/w in MtBE5 mL
ACCU-D-5441-10X-5ML-PAKASTM D5441 MtBE Contaminant Std, High Conc,, 1,0 % w/w in MtBE5 x 5 mL
ACCU-D-5441-10X-PAKASTM D5441 MtBE Contaminant Std, High Conc,, 1,0 % w/w in MtBE5 x 1 mL
ACCU-D-5441-5MLASTM D5441 MtBE Contaminant Std, Low Conc,, 0,1 % w/w in MtBE5 mL
ACCU-D-5441-5ML-PAKASTM D5441 MtBE Contaminant Std, Low Conc,, 0,1 % w/w in MtBE5 x 5 mL
ACCU-D-5441-PAKASTM D5441 MtBE Contaminant Std, Low Conc,, 0,1 % w/w in MtBE5 x 1 mL
ACCU-D-5441-QUALD-5441 Qualitative Standard, 0,1% wt/wt in Dodecane1 mL
ACCU-D-5441-QUANT-R1D-5441 Quantitative Standard, Varied conc, in n-Dodecane1 mL
ACCU-D-5441-RESASTM D5441 MtBE Resolution Test Mix, 1,0 % w/w in MtBE1 mL
ACCU-D-5441-RES-5MLASTM D5441 MtBE Resolution Test Mix, 1,0 % w/w in MtBE5 mL
ACCU-D-5441-RES-5ML-PAKASTM D5441 MtBE Resolution Test Mix, 1,0 % w/w in MtBE5 x 5 mL
ACCU-D-5441-RES-PAKASTM D5441 MtBE Resolution Test Mix, 1,0 % w/w in MtBE5 x 1 mL
ACCU-D-5442D-5442 Quantitative Wax Standard, Varied conc, in Cyclohexane1 mL

Page:1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32